24/7 Rapid Response · Gate, boom or fence down? Call 0400 101 132
Access · Automation · Managed securityMelbourne-based · Australia-wideCompliance-led site delivery24/7 emergency: 0400 101 132MagicKeys
Illustrative image

Access integration

Integrated Access Systems

RJL Commercial Group designs and integrates commercial access systems across Melbourne and Victoria from Thomastown. We coordinate credentials, intercoms, automatic number plate recognition (ANPR), gate automation and supported OPTEX detection, with above-ground virtual loop options that avoid cutting an inductive loop into the road. Our fully customisable MagicKeys Access Portal, developed in-house over two years, gives enterprise clients a custom-built management option backed by the same team that assesses, installs and maintains the site.

Key Points

Technician testing an access control board with a multimeter

How RJL connects a site

Fewer separate systems. Fewer call-outs.

01

Wiegand

  • Card, fob and keypad readers
  • Readers and controllers from different brands, confirmed on site
  • Gate operators and boom gates
  • Used across almost every RJL install
02

Virtual relays

  • Phone call opens the gate
  • Button in the MagicKeys portal or app
  • Links one system to another without extra hardware
03

Optex & anti-tailgating

  • Full Optex range supplied and installed
  • Vehicle detection and safety sensors
  • Anti-tailgating devices for gates, booms and doors

Buyer's guide

Integrated access: what you need to know

Integration links the parts of an entry so they work as one: readers talk to the gate controller over Wiegand, sensors tell the boom a car is waiting, cameras read plates, and the MagicKeys portal manages it all.

Done well, it means fewer call-outs and fewer separate systems. It does need careful design and testing, because every brand handles signals a little differently.

Pros

  • One system to manage instead of three or four
  • Above-ground detection (Optex) avoids cutting loops into the road
  • Anti-tailgating helps stop a second car following the first
  • Phone, app, card, PIN and ANPR access all on the same entry
  • Reuses existing readers and controllers where they are compatible

Cons

  • Takes more design and testing time than a single product
  • Each brand interface must be confirmed on site
  • Network and power must be reliable
  • Firmware updates on one device can affect another, so changes need care

A good fit for your site if

  • You have several access methods or brands to tie together
  • Tailgating or loop failures are a problem
  • You want one portal for many sites

Detection and camera hardware we integrate

Ratings are the manufacturer's published maximums for a well-built gate on level ground. RJL picks a motor with headroom after checking gate weight, wind load, slope and how many times a day the gate runs. Ranges change, so we confirm the current model when we quote.

Gate style or siteExample modelsWhy it suits
Vehicle detection without cutting the roadOptex OVS-01GT vehicle presence sensorMounted above ground. Uses microwave and ultrasonic sensing to detect a stopped vehicle within 5.5m, so it can replace an in-ground loop. Works day and night.
Number plate recognition (ANPR) at gates and boomsHikvision DS-TCG406-E (4MP access ANPR camera) · Dahua ITC413-PW4D series (access ANPR camera)Reads plates as the car arrives and opens for approved vehicles. No cards or remotes needed.
Safety beams, anti-tailgating and gate safetyOptex safety and detection sensors · photocells and safety edges matched to the operatorStops the gate or boom closing on a person or vehicle and helps catch tailgaters.
Intercoms and CCTVHikvision and Dahua IP video intercoms and camerasVisitors call a phone or concierge, and video is recorded at the entry.

Recent work and examples

Brands we supply, install and service

  • Roger Technology
  • CAME
  • BFT
  • Centurion (CENTSYS)
  • SEA
  • DEA System
  • Optex
  • Hikvision
  • Dahua

More questions

What is Wiegand?

A standard way for card readers and keypads to send a user code to a controller. Most RJL installs use it to connect readers from one brand to controllers or gate boards from another.

Why use an Optex sensor instead of a loop?

The Optex OVS-01GT sits above ground and detects a waiting vehicle within 5.5m. No saw-cutting, no broken loops when the slab cracks, and it can be moved later.

Frequently asked questions

Useful answers before you contact the team.

What is Wiegand?

The standard “language” most card readers, fob readers and keypads use to talk to a controller. Almost everything RJL installs works on Wiegand, so readers and controllers from different brands can often be connected. RJL confirms it on site.

What is a virtual relay?

A switch that exists in software instead of a box on the wall. RJL uses them so a phone call opens a gate, so a button in the MagicKeys portal or app opens it, and to link one system to another, such as an Optex sensor or a Wiegand reader triggering a gate operator, without extra hardware.

Are you an Optex dealer?

RJL supplies and installs the Optex range. We do not claim to be an Optex dealer or partner.

Related projects, services and guides

Start a conversation

Get your systems talking to each other.

Book a free on-site maintenance report, or call the 24/7 Rapid Response line for anything urgent.

Free maintenance report